Purchasing Guides

Garden Gate Width Explained: Leaf Width, Post Spacing and Clear Opening

A garden gate can match the width printed on a quotation and still leave less usable access than the buyer expected. For mesh gate orders, define the passage requirement and the available opening before settling the leaf size.

Measurement route

Establish the access needed, survey the opening, then approve a drawing that connects the posts, moving leaf and selected hardware.

Quick Answer

Garden gate width needs a reference point. Leaf width describes the moving frame. Inside post spacing measures the gap between the facing post surfaces. Post-centre distance sets out the support positions. Clear opening describes the usable passage with the gate in its specified open position. Begin with the access the site needs, then check the posts, hinge position, latch and opening arc together. For existing posts, send actual measurements at several heights. For a new installation, approve the complete gate drawing before fixing the post positions. Ask the supplier to label each width rather than quote one unqualified “gate size.”

Table of contents

Start with the Passage You Need

Think about what will move through the entrance: people, a garden trolley, maintenance equipment or occasional deliveries. Record the required usable width and any equipment height that affects passage. Include the approach to the gate, particularly where a path turns immediately before or after the opening.

A narrow approach may make a straight-through measurement inadequate for moving a loaded trolley. A nearby wall may limit how far the leaf can swing. Show these features on the site sketch so the proposed gate can be reviewed in its surroundings.

Keep the access requirement and the measured site opening as separate entries. The first states what the finished entrance must provide; the second describes the space available to build it. The supplier can then identify a suitable leaf and hardware arrangement, or flag where the proposed opening needs adjustment.

For a group of gates, give each opening an identifier. Similar-looking entrances can have different post sizes, swing directions or access needs. A gate schedule should preserve those differences through quotation and production.

Put Four Widths on the Drawing

An elevation shows the gate closed and helps explain frame size. A plan view shows the hinge position, swing direction and space available when it opens. Together, the two views make a dimensional offer much easier to check.

Dimension Reference to show What it helps the buyer decide
Leaf width The left and right limits of the moving frame, with any additional projections identified separately Which manufactured leaf is required
Inside post spacing The facing surfaces of the two supports, at the stated measurement level How much space is available for the closed gate and its side allowances
Post-centre distance The marked centre lines of the support sections Where new posts are set out and how an existing layout is described
Clear opening The unobstructed passage at the stated open position and measurement location Whether the completed entrance provides the intended access
Closed mesh gate showing leaf width, inside post spacing and post-centre distance.
Figure A. Reference points for the closed-gate widths: the moving leaf, inside post faces and post centres.
Select the diagram to open the full-size version.

Read the wording beside the dimension arrows. A catalogue may use a nominal size to identify a gate kit, while the manufacturing drawing gives the actual frame dimension. Request the drawing associated with the quoted product code.

Manufacturer measurement forms demonstrate the value of separating these entries. For example, the Jacksons gate measurement form records actual gate width, width between posts and opening direction independently. For a steel mesh gate, use the dimensions and allowances belonging to the selected frame and fittings.

Convert Post Centres into Inside Spacing

When two upright square posts are aligned across an opening, their centre spacing includes half the width of each post. Deduct those two half-widths to find the distance between their inside faces.

Inside spacing = post-centre distance − half the left post width − half the right post width.

Use the post dimensions measured along the same line as the opening. For rectangular posts, show the section orientation: rotating a section changes the dimension that occupies the opening.

Worked layout example

Assume two upright, parallel square posts, each 60 mm wide, with their centres 1,200 mm apart. Their faces are aligned with the opening measurement line.

Item Calculation or dimension
Post-centre distance 1,200 mm
Half-width of left post 30 mm
Half-width of right post 30 mm
Inside spacing 1,200 − 30 − 30 = 1,140 mm

The 1,140 mm result describes the space between the post faces. Next, use the hinge and latch details to size the leaf. Check usable passage separately with the gate drawn open.

For a single leaf sitting entirely between posts on the closing line, the width chain can be written as:

Inside spacing = hinge-side allowance + leaf frame width + latch-side allowance.

Take each allowance from the selected connection detail. A face-mounted or offset arrangement has a different geometry and should be read from its plan drawing. Leave the leaf dimension for supplier confirmation until that relationship is settled.

Survey Posts That Are Already Installed

Existing supports make the survey the starting point. Measure the gap near the lower hinge level, near the upper hinge level and at an intermediate position. Record the height of each reading. If the values differ, ask the installer to assess alignment and the fitting arrangement before ordering the replacement leaf.

Photograph each post with a scale visible and record its outside section dimensions. Where existing fittings will remain, include their mounting positions, fixing-hole pattern and hinge arrangement. The supplier needs the connection details as well as the distance across the opening.

Use a simple survey checklist:

  1. Identify the opening and mark which side is viewed as the outside.
  2. Record the post-to-post readings at the selected heights.
  3. Show post section sizes, orientation and any visible lean or misalignment.
  4. Identify retained hinges, latch parts and mounting plates.
  5. Mark finished ground levels and any rise across the swing area.
  6. Show walls, kerbs, fence returns and other nearby obstructions.
  7. Record the required passage and the intended opening direction.

For a complete new gate set, review the gate post options together with the proposed leaf. Post section, wall thickness, mounting and foundation details should suit the selected gate assembly and site design. The gap calculation alone is a dimensional check; post selection also needs the gate's structural requirements.

Account for the Hinge and the Opening Arc

The hinge axis determines how the leaf moves relative to the post. Its offset can change the side allowance, the position of the open leaf and the available passage. The latch, keep, handles and stops can also project into the space used by people or equipment.

Ask for the hinge and latch model or a dimensioned connection detail. Where adjustment is available, agree the intended setting and the allowance left for fitting. Request the mounting dimensions with the quotation so the installer can check the gate-to-post relationship before fixing the hardware. Establish the final width chain from that selected detail.

Show the open position, not just an arrow

Specify the intended opening angle and draw the leaf in that position. Check the space occupied by its frame and hardware, plus any wall or fence that limits travel. Where the project specifies a clear-opening measurement method or angle, use it on this view.

Plan view comparing inside post spacing with usable passage at a shown 90-degree gate position.
Figure B. A separate 90° opening example showing the passage between the open leaf and latch keep at the marked section.
Select the diagram to open the full-size version.

The ground beneath the swing also matters. A leaf that clears the closed position may meet rising ground farther along its path. Record the finished surface across the arc and have the installer review the operating clearance.

Define left and right from one viewpoint

Mark a viewing direction on the drawing, then identify the hinge side and whether the leaf opens inward or outward. Keep that convention on the gate schedule and quotation. An unlabelled “left-hand gate” is easy to interpret differently when the supplier and installer are looking from opposite sides.

Check Everyday Access on Double Gates

For a double-leaf entrance, record two operating conditions: the opening used routinely and the wider opening used when both leaves move. If one leaf normally remains secured, check the usable passage with that leaf in its normal position.

Equal leaves can suit a symmetrical entrance. Unequal leaves may be considered where a smaller daily-use leaf and a wider occasional opening serve different needs. Show the active leaf, the closing sequence and any centre latch or drop-bolt arrangement in the proposed configuration.

The width schedule should identify each frame separately, the meeting arrangement and both outside hinge connections. A central overlap strip or projecting fitting changes how the pair is described, so include it on the detail. Approve the complete dimensional chain rather than splitting the measured gap into two assumed leaf sizes.

If the gate is supplied with a longer fence run, coordinate the adjoining connections as well. The Euro fence and garden gate sourcing guide covers the broader roll mesh, post, gate and accessory package.

Send a Measured Opening Record

The most useful quotation request gives the supplier both the required outcome and the known dimensions. Keep unknown leaf or hardware dimensions open for a proposed drawing rather than filling them with a guessed deduction.

Information to send Entry for each opening
Opening reference and quantity __________
Everyday use and required passage __________
Existing posts or complete new gate set __________
Inside-gap readings and measurement heights __________
Post sections, orientation and centre spacing where known __________
Single leaf or double leaf; active leaf if applicable __________
Viewing direction, hinge side and swing direction __________
Ground levels and nearby obstructions __________
Hardware to retain or hardware for supplier selection __________
Gate height, infill, finish and adjoining fence __________
Delivery destination and any drawing requirements __________

Attach the measured sketch and photographs to the inquiry. The RFQ Specification Builder can organize the accompanying product information; keep the opening record with it so the width references remain visible.

Before approval, check that the returned drawing answers four questions: What leaf will be made? Where will the posts sit? How will the selected fittings connect? What passage will remain in the intended open position?

Buyer Questions

Does a “1 m garden gate” provide a 1 m clear opening?

Check what the supplier's 1 m designation refers to. It may describe the moving frame or a nominal gate-set opening. Request the inside post dimension and the usable passage shown at the agreed open position before approving the size.

Can a new leaf be ordered from the old leaf's width alone?

Measure the old frame, then add the installed opening, hinge positions and latch details. This helps the supplier reproduce the relevant interfaces and check whether the retained fittings suit the proposed replacement.

Should the two leaves of a double gate be the same size?

Choose the arrangement around everyday and occasional access. Record the size of each leaf and check the passage available with the active leaf open. The meeting detail and hardware should be specified for that arrangement.

What if the hinge model changes after the drawing is approved?

Recheck the gate-to-post allowances, mounting positions and open-position clearance against the revised hardware. Update the drawing before manufacturing or setting out posts so all teams work from the same dimensions.

Discuss a Garden Gate That Fits the Opening

Explore ANJIA's garden gates for fence systems and send the opening record with your required quantities, infill and finish. Our team can review the available information and identify the dimensions needed for a gate quotation.

Get a Free Business Quote

About ANJIA GROUP

ANJIA GROUP supplies wire mesh, fencing and related industrial products for global B2B buyers. Contact our team to discuss product specifications, matching accessories and export packing.

Discuss your sourcing requirements

Send your product requirements and any relevant drawings to our team.

Get a Free Business Quote

Continue Sourcing

Recommended Products

Garden gate product referenceGarden GatesFence post product referenceFence Posts
Scroll to Top

Business Quote

Tell us what you need. We’ll help confirm the details and prepare a quote for your order.

ANJIA Quick Inquiry
Talk to us via WhatsApp nowOpen Full Inquiry Form